PRODUCTS

/ Wedge flowmeter

Wedge flowmeter

MODEL: DPF7900 Series

CBRO Wedge Flow meter is mainly used for flow measurement of high viscosity heavy oil, residual oil, diesel oil, industrial gas, coke oven gas, blast furnace gas, producer gas, city gas, hydrogen, nitrogen, air, steam, liquids and other media of the sewage.

Product ·Structure diagram

Product Internal Structure|Decomposition Analysis|Just to give you a better understanding of the product
Committed to provide solution for field instruments

Product • parameters

Various parameters for you to choose|HUAHAI instrument Strive for excellence
Committed to provide solution for field instruments

Product name
Wedge flowmeter
Applicable pipe diameter D
15mm~300mm (More than DN300 can be made)
Uncertainty
±1.0~1.5% FS(When leaving the factory, calibrate one by one)
Repeatability
0.2~0.5%
Range ratio
10:1
Working pressure
-0.1Mpa~6.4Mpa
Working temperature
-50℃~400℃
Minimum flow velocity
0.01m/s
Measuring liquid viscosity
Upper limit 500mPa.S
Reynolds number range
Lower limit 300,upper limit more than 1*106
Applicable medium
Water, sewage, gas, steam, high viscosity liquid,solid-liquid mixed type

Product Dimensions

Nominal diameter D
L (mm)
Nominal diameter D
L (mm)
Nominal diameter D
L (mm)
DN15
400
DN65
450
DN150
600
DN25
400
DN80
480
DN200
620
DN40
400
DN100
520
DN250
650
DN50
400
DN125
550
DN300
700

Flange execution standard:JB/T81-1994、JB/T82.1-1994、JB/T82.2-1994(the picture above)

Product Selection

Model
Description
HLGX
Wedge flowmeter
Code
Classification by structure characteristics
Y
Integral type wedge flowmeter
F
Remote type wedge flowmeter
Code
Nominal pressure(MPa)
1.6
1.6
2.0
2.0
2.5
2.5
4.0
4.0
6.4
6.4
Code
Caliber
15-300
DN15-DN300
Code
Medium
1
Liquid
2
Gas
3
Steam
Code
Compensation form
N
No pressure, temperature compensation
P
With pressure compensation output
T
With temperature compensation output
Code
Transmitter differential pressure range
1
Medium differential pressure range
2
High differential pressure range
Code
Whether with the field display
W
Throttling device sensor
X
Intelligent throttling device (flowmeter)

Flange execution standard:JB/T81-1994、JB/T82.1-1994、JB/T82.2-1994(the picture above)

Selection Notes

1. Pipe diameter: pipe diameter, wall thickness and material
2、Measuring medium
3、Medium temperature (℃)
4、Medium working pressure(MPa):Maximum pressure, normal pressure, minimum pressure
5、Medium working flow (m3/h、kg/h、Nm3/h) :Maximum flow, normal flow, minimum flow
6、Medium viscosity (mPa.s)
7、Medium density (kg/m3)

Installation Diagram

Installation Precautions

The upstream and downstream sides of wedge flowmeter should be configured straight pipe section, the length of the straight pipe section is shown in the following table

 

Shortest straight pipe section of the upstream side (Numerical value multiplied by multiples of pipeline inner diameter)
Wedge ratio
Elbow 90°
Tee joint
Ball valve
Gate valve (full open)
H/D
6
6
10
6
0.2
8
8
11
6
0.3
12
12
14
8
0.4
14
14
16
10
0.4

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!